{"id":29,"date":"2022-07-20T11:25:04","date_gmt":"2022-07-20T09:25:04","guid":{"rendered":"https:\/\/grupos.unican.es\/magnetismo\/?page_id=29"},"modified":"2026-01-16T10:37:23","modified_gmt":"2026-01-16T09:37:23","slug":"scientific-tech-services","status":"publish","type":"page","link":"https:\/\/grupos.unican.es\/magnetismo\/scientific-tech-services\/","title":{"rendered":"Facilities"},"content":{"rendered":"\n<hr class=\"wp-block-separator has-alpha-channel-opacity is-style-wide\"\/>\n\n\n\n<p class=\"has-foreground-color has-text-color\" style=\"font-size:1.3rem\">The scientific and technical services provided by the Magnetism in Matter group are within the general facilities of the Universidad de Cantabria.<\/p>\n\n\n\n<p class=\"has-foreground-color has-text-color has-small-font-size\" style=\"font-size:1.3rem\">Please send an email to the person in charge indicated below and, we will contact you for more details and to offer you a service quotation.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity is-style-wide\"\/>\n\n\n\n<p class=\"has-background-color has-primary-background-color has-text-color has-background\" style=\"font-size:1.5rem\">Experienced Users of Magnetic characterization services<\/p>\n\n\n\n<p class=\"has-small-font-size\">Person in charge: <a href=\"mailto:espesoji@unican.es\" data-type=\"mailto\" data-id=\"mailto:espesoji@unican.es\" target=\"_blank\" rel=\"noreferrer noopener\">Jose I. Espeso<\/a><\/p>\n\n\n\n<div class=\"wp-block-media-text alignwide is-stacked-on-mobile\"><figure class=\"wp-block-media-text__media\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"768\" src=\"https:\/\/grupos.unican.es\/magnetismo\/wp-content\/uploads\/2022\/07\/20220711_123403-1-1024x768.jpg\" alt=\"\" class=\"wp-image-357 size-full\" srcset=\"https:\/\/grupos.unican.es\/magnetismo\/wp-content\/uploads\/2022\/07\/20220711_123403-1-1024x768.jpg 1024w, https:\/\/grupos.unican.es\/magnetismo\/wp-content\/uploads\/2022\/07\/20220711_123403-1-300x225.jpg 300w, https:\/\/grupos.unican.es\/magnetismo\/wp-content\/uploads\/2022\/07\/20220711_123403-1-768x576.jpg 768w, https:\/\/grupos.unican.es\/magnetismo\/wp-content\/uploads\/2022\/07\/20220711_123403-1-1536x1152.jpg 1536w, https:\/\/grupos.unican.es\/magnetismo\/wp-content\/uploads\/2022\/07\/20220711_123403-1-2048x1536.jpg 2048w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure><div class=\"wp-block-media-text__content\">\n<p class=\"has-primary-color has-text-color has-small-font-size\">UC counts with a SQUID magnetometer QD-MPMS  that is able to determine extremely low magnetization signals present in the material under study. This magnetization can be evaluated under several conditions of external magnetic field and temperature. The core system consists of a superconducting longitudinal solenoid able to generate mangetic fields up to 5 Tesla. The system has also able to precisely control the temperature at the sample space at any value from 2K to 400K with a stability condition of les than 0.1% of oscillation. Pressure cell up to 15 kbar. This system runs under SERCAMAT UC general services, which is lead by Jose I. Espeso as Scientifc Head (a member of our Group). Our group is a major and experienced user of this sophisticaded magnetometer. More info <a href=\"https:\/\/web.unican.es\/unidades\/scti\/servicio-de-caracterizacion-de-materiales-sercamat\/tarifas-sercamat\">SERCAMAT<\/a><\/p>\n<\/div><\/div>\n\n\n\n<div style=\"height:43px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity is-style-wide\"\/>\n\n\n\n<div class=\"wp-block-media-text alignwide is-stacked-on-mobile\"><figure class=\"wp-block-media-text__media\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"768\" src=\"https:\/\/grupos.unican.es\/magnetismo\/wp-content\/uploads\/2022\/07\/20220711_123224-2-1024x768.jpg\" alt=\"\" class=\"wp-image-368 size-full\" srcset=\"https:\/\/grupos.unican.es\/magnetismo\/wp-content\/uploads\/2022\/07\/20220711_123224-2-1024x768.jpg 1024w, https:\/\/grupos.unican.es\/magnetismo\/wp-content\/uploads\/2022\/07\/20220711_123224-2-300x225.jpg 300w, https:\/\/grupos.unican.es\/magnetismo\/wp-content\/uploads\/2022\/07\/20220711_123224-2-768x576.jpg 768w, https:\/\/grupos.unican.es\/magnetismo\/wp-content\/uploads\/2022\/07\/20220711_123224-2-1536x1152.jpg 1536w, https:\/\/grupos.unican.es\/magnetismo\/wp-content\/uploads\/2022\/07\/20220711_123224-2-2048x1536.jpg 2048w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure><div class=\"wp-block-media-text__content\">\n<p class=\"has-text-align-left has-primary-color has-text-color has-small-font-size\">The REMAGRAPH \u00ae C is a hysteresigraph for taking quasi-static (DC) measurements on soft magnetic material<\/p>\n\n\n\n<p class=\"has-text-align-left has-primary-color has-text-color has-small-font-size\">The REMAGRAPH \u00ae C allows measuring a variety of materials with different magnetic properties, for example: Soft magnetic steel, Electrical steel, Ferrous alloys, Soft magnetic ferrites, Crystalline Ni-Fe alloys and compounds, Amorphous magnetic materials, Nanocrystalline alloys, Soft magnetic composites (SMC).<\/p>\n<\/div><\/div>\n\n\n\n<p class=\"has-background-color has-primary-background-color has-text-color has-background\" style=\"font-size:1.5rem\">X-ray Diffraction characterization services<\/p>\n\n\n\n<p class=\"has-small-font-size\">Person in charge: <a href=\"mailto:espesoji@unican.es\" data-type=\"mailto\" data-id=\"mailto:espesoji@unican.es\" target=\"_blank\" rel=\"noreferrer noopener\">Jose I. Espeso<\/a><\/p>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-28f84493 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:33.33%\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"277\" height=\"420\" src=\"https:\/\/grupos.unican.es\/magnetismo\/wp-content\/uploads\/2022\/07\/XRD_Bruker.png\" alt=\"\" class=\"wp-image-188\" srcset=\"https:\/\/grupos.unican.es\/magnetismo\/wp-content\/uploads\/2022\/07\/XRD_Bruker.png 277w, https:\/\/grupos.unican.es\/magnetismo\/wp-content\/uploads\/2022\/07\/XRD_Bruker-198x300.png 198w\" sizes=\"auto, (max-width: 277px) 100vw, 277px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:66.66%\">\n<p class=\"has-primary-color has-text-color has-small-font-size\">This service aims to support basic and applied research, in different areas of knowledge; especially&nbsp;on Chemistry, Physics, Geology and Materials Science.<br>With a long background since&nbsp;2000, it provides&nbsp;supports to different national and international research group and companies for identification of minerals and other crystalline phases in prospecting for mineral deposits, rocks and industrial minerals, samples of rocks, soils, archaeological remains (ceramics, bones, teeth, etc.), industrial and construction materials, catalysts, industrial refractories, sand, medicines,&nbsp;among&nbsp;others. In addition, the service has been approved by the U.S. Food and Drug Administration (FDA) for testing&nbsp;certain chemicals used in the&nbsp;pharmacological&nbsp;industry.<\/p>\n<\/div>\n<\/div>\n\n\n\n<p>Equipment<\/p>\n\n\n\n<p class=\"has-primary-color has-text-color has-small-font-size\"><strong>Bruker D8 Advance<\/strong>: Operates with Theta-Theta geometry, with Cu&nbsp;K-alpha&nbsp;radiation and a&nbsp;linear&nbsp;LynxEye detector.&nbsp;It can be used&nbsp;with different sample holders&nbsp;and&nbsp;a spinner to improve the statistics of the measurements.&nbsp;&nbsp;For users who require it, phase identification is carried out using specific software, in combination with the ICDD&nbsp;and COD&nbsp;databases.&nbsp;The results obtained are sent to users in the form of reports, graphs and\/or tables. Likewise,&nbsp;this provided information&nbsp;includes&nbsp;the&nbsp;specifications of the used equipment,&nbsp;measuring&nbsp;conditions, methodology for preparing the samples, etc.<\/p>\n\n\n\n<p class=\"has-primary-color has-text-color has-small-font-size\">The D8 Advance diffractometer from Bruker is equiped with a high temperature camera (up to 1200\u00baC), as well as a low temperature camera at cryogenic temperatures (LN2).<\/p>\n\n\n\n<p class=\"has-small-font-size\"><\/p>\n\n\n\n<p class=\"has-background-color has-primary-background-color has-text-color has-background\" style=\"font-size:1.5rem\"><strong>Low temperature scanning tunneling microscope<\/strong> &#8211; LT-STM<\/p>\n\n\n\n<p class=\"has-small-font-size\">Person in charge: <a href=\"mailto:cesar.moreno@unican.es\" data-type=\"mailto\" data-id=\"mailto:cesar.moreno@unican.es\" target=\"_blank\" rel=\"noreferrer noopener\">C\u00e9sar Moreno Sierra<\/a><\/p>\n\n\n\n<div class=\"wp-block-media-text alignwide is-stacked-on-mobile\"><figure class=\"wp-block-media-text__media\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"768\" src=\"https:\/\/grupos.unican.es\/magnetismo\/wp-content\/uploads\/2025\/02\/STMlab2-1-1024x768.png\" alt=\"\" class=\"wp-image-674 size-full\" srcset=\"https:\/\/grupos.unican.es\/magnetismo\/wp-content\/uploads\/2025\/02\/STMlab2-1-1024x768.png 1024w, https:\/\/grupos.unican.es\/magnetismo\/wp-content\/uploads\/2025\/02\/STMlab2-1-300x225.png 300w, https:\/\/grupos.unican.es\/magnetismo\/wp-content\/uploads\/2025\/02\/STMlab2-1-768x576.png 768w, https:\/\/grupos.unican.es\/magnetismo\/wp-content\/uploads\/2025\/02\/STMlab2-1.png 1280w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure><div class=\"wp-block-media-text__content\">\n<p class=\"has-primary-color has-text-color has-small-font-size\">Low temperature scanning tunnelling microscope (Omicron NanoTechnology GmbH LT STM with Matrix controller) operated in ultra-high vacuum (UHV, low 10<sup>-10<\/sup> mbar vacuum), variable temperature (300 K, ~78 K (with LN2) and ~5 K (with LHe)) and coupled to a preparation UHV chamber equipped with resistive heater (up to 800\u00baC), ion sputtering gun (IQE 11\/35 SPECS), 3-cell Kentax evaporator with cooling for organic materials, lock-in amplifier (SR830, Stanford Research Systems) and residual gas analyzer (RGA).<\/p>\n\n\n\n<p class=\"has-primary-color has-text-color has-small-font-size\">Coarse motion piezo drivers x\/y\/z: 2.5\/2.5\/10 mm Scan range: 10&#215;10 \u00b5m<sup>2&nbsp;<\/sup>(@ 300 K), 4.4&#215;4.4 \u00b5m<sup>2&nbsp;<\/sup>(@ 77 K) and 1.8&#215;1.8 \u00b5m<sup>2&nbsp;<\/sup>(@ 5 K); Sample size: 1&#215;1 cm<sup>2<\/sup><\/p>\n\n\n\n<p class=\"has-primary-color has-text-color has-small-font-size\">It allows for the preparation and imaging of conductive surfaces in a UHV environment, down to the atomic scale.<\/p>\n<\/div><\/div>\n\n\n\n<p class=\"has-background-color has-primary-background-color has-text-color has-background\" style=\"font-size:1.5rem\">Atomic Force Microscopy (AFM)<\/p>\n\n\n\n<p class=\"has-small-font-size\">Person in charge: <a href=\"mailto:cesar.moreno@unican.es\" data-type=\"mailto\" data-id=\"mailto:cesar.moreno@unican.es\" target=\"_blank\" rel=\"noreferrer noopener\">C\u00e9sar Moreno Sierra<\/a><\/p>\n\n\n\n<div class=\"wp-block-media-text alignwide is-stacked-on-mobile\" style=\"grid-template-columns:25% auto\"><figure class=\"wp-block-media-text__media\"><img loading=\"lazy\" decoding=\"async\" width=\"356\" height=\"512\" src=\"https:\/\/grupos.unican.es\/magnetismo\/wp-content\/uploads\/2025\/02\/AFM2-1.jpg\" alt=\"\" class=\"wp-image-679 size-full\" srcset=\"https:\/\/grupos.unican.es\/magnetismo\/wp-content\/uploads\/2025\/02\/AFM2-1.jpg 356w, https:\/\/grupos.unican.es\/magnetismo\/wp-content\/uploads\/2025\/02\/AFM2-1-209x300.jpg 209w\" sizes=\"auto, (max-width: 356px) 100vw, 356px\" \/><\/figure><div class=\"wp-block-media-text__content\">\n<p class=\"has-primary-color has-text-color has-small-font-size\">ezAFM+ from Nanomagnetics with scan head 40x40x4 \u00b5m<\/p>\n\n\n\n<p class=\"has-primary-color has-text-color has-small-font-size\">XY motorized sample positioner has a 38\u00d738 mm range with 1\u00b5m resolution<\/p>\n\n\n\n<p class=\"has-primary-color has-text-color has-small-font-size\"><strong>Scanning modes<\/strong><\/p>\n\n\n\n<p class=\"has-primary-color has-text-color has-small-font-size\">Contact Mode <\/p>\n\n\n\n<p class=\"has-primary-color has-text-color has-small-font-size\">Dynamic Mode (Tapping Mode) <\/p>\n\n\n\n<p class=\"has-primary-color has-text-color has-small-font-size\">Kelvin Probe Force Microscopy (KPFM) <\/p>\n\n\n\n<p class=\"has-primary-color has-text-color has-small-font-size\">Magnetic Force Microscopy (MFM)<\/p>\n\n\n\n<p class=\"has-primary-color has-text-color has-small-font-size\"> f-d Spectroscopy<\/p>\n<\/div><\/div>\n\n\n\n<p class=\"has-background-color has-primary-background-color has-text-color has-background\" style=\"font-size:1.5rem\">Liquid Nitrogen Generator (LN20AC Compact)<\/p>\n\n\n\n<p class=\"has-small-font-size\">Person in charge: <a href=\"mailto:cesar.moreno@unican.es\" data-type=\"mailto\" data-id=\"mailto:cesar.moreno@unican.es\" target=\"_blank\" rel=\"noreferrer noopener\">C\u00e9sar Moreno Sierra<\/a><\/p>\n\n\n\n<div class=\"wp-block-media-text alignwide is-stacked-on-mobile\" style=\"grid-template-columns:45% auto\"><figure class=\"wp-block-media-text__media\"><img loading=\"lazy\" decoding=\"async\" width=\"905\" height=\"1024\" src=\"https:\/\/grupos.unican.es\/magnetismo\/wp-content\/uploads\/2025\/03\/LN2_3-905x1024.png\" alt=\"\" class=\"wp-image-717 size-full\" srcset=\"https:\/\/grupos.unican.es\/magnetismo\/wp-content\/uploads\/2025\/03\/LN2_3-905x1024.png 905w, https:\/\/grupos.unican.es\/magnetismo\/wp-content\/uploads\/2025\/03\/LN2_3-265x300.png 265w, https:\/\/grupos.unican.es\/magnetismo\/wp-content\/uploads\/2025\/03\/LN2_3-768x869.png 768w, https:\/\/grupos.unican.es\/magnetismo\/wp-content\/uploads\/2025\/03\/LN2_3.png 961w\" sizes=\"auto, (max-width: 905px) 100vw, 905px\" \/><\/figure><div class=\"wp-block-media-text__content\">\n<p class=\"has-foreground-color has-text-color has-small-font-size\"><strong>LN2 production<\/strong>:  up to 20 litres per day<\/p>\n\n\n\n<p class=\"has-foreground-color has-text-color has-small-font-size\"><strong>LN2 purity<\/strong>: &gt;99% (&lt;1.0% O2)<\/p>\n\n\n\n<p class=\"has-foreground-color has-text-color has-small-font-size\">35 litre LN2 storage dewar<\/p>\n<\/div><\/div>\n\n\n\n<p class=\"has-background-color has-primary-background-color has-text-color has-background\" style=\"font-size:1.5rem\">Price list<\/p>\n\n\n\n<figure class=\"wp-block-image size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"766\" height=\"596\" src=\"https:\/\/grupos.unican.es\/magnetismo\/wp-content\/uploads\/2025\/12\/tarifas2025XRD.png\" alt=\"\" class=\"wp-image-759\" style=\"aspect-ratio:0.8307291666666666;width:461px;height:auto\" srcset=\"https:\/\/grupos.unican.es\/magnetismo\/wp-content\/uploads\/2025\/12\/tarifas2025XRD.png 766w, https:\/\/grupos.unican.es\/magnetismo\/wp-content\/uploads\/2025\/12\/tarifas2025XRD-300x233.png 300w\" sizes=\"auto, (max-width: 766px) 100vw, 766px\" \/><\/figure>\n","protected":false},"excerpt":{"rendered":"<p>The scientific and technical services provided by the Magnetism in Matter group are within the general facilities of the Universidad de Cantabria. Please send an email to the person in charge indicated below and, we will contact you for more details and to offer you a service quotation. Experienced Users of Magnetic characterization services Person [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":282,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-29","page","type-page","status-publish","has-post-thumbnail","hentry"],"_links":{"self":[{"href":"https:\/\/grupos.unican.es\/magnetismo\/wp-json\/wp\/v2\/pages\/29","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/grupos.unican.es\/magnetismo\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/grupos.unican.es\/magnetismo\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/grupos.unican.es\/magnetismo\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/grupos.unican.es\/magnetismo\/wp-json\/wp\/v2\/comments?post=29"}],"version-history":[{"count":64,"href":"https:\/\/grupos.unican.es\/magnetismo\/wp-json\/wp\/v2\/pages\/29\/revisions"}],"predecessor-version":[{"id":769,"href":"https:\/\/grupos.unican.es\/magnetismo\/wp-json\/wp\/v2\/pages\/29\/revisions\/769"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/grupos.unican.es\/magnetismo\/wp-json\/wp\/v2\/media\/282"}],"wp:attachment":[{"href":"https:\/\/grupos.unican.es\/magnetismo\/wp-json\/wp\/v2\/media?parent=29"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}