{"id":150,"date":"2018-06-20T11:16:40","date_gmt":"2018-06-20T11:16:40","guid":{"rendered":"https:\/\/grupos.unican.es\/pasep\/?page_id=150"},"modified":"2018-06-21T10:56:18","modified_gmt":"2018-06-21T10:56:18","slug":"analytical-facilites","status":"publish","type":"page","link":"https:\/\/grupos.unican.es\/pasep\/analytical-facilites\/","title":{"rendered":"ANALYTICAL FACILITES"},"content":{"rendered":"<table>\n<tbody>\n<tr>\n<td style=\"background-color: #a8a49d; text-align: center;\" colspan=\"2\">\n<h3><span style=\"color: #ffffff;\"><strong>ENVIRONMENTAL PARAMETERS<\/strong><\/span><\/h3>\n<\/td>\n<\/tr>\n<tr>\n<td><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-161\" src=\"https:\/\/grupos.unican.es\/pasep\/wp-content\/uploads\/2018\/06\/COT.jpg\" alt=\"\" width=\"296\" height=\"197\" \/><\/td>\n<td>\n<p style=\"text-align: justify;\">Total Organic Carbon (TOC) (UNE-EN 1484:1997)<\/p>\n<p style=\"text-align: justify;\">Chemical Oxygen Demand (COD) \u2013 Closed reflux and colorimetric analysis method (UNE-EN 77004:2002)<\/p>\n<p style=\"text-align: justify;\">Biological Oxygen Demand (BOD) \u2013 Manometric method (Oxitop) (UNE-EN 1899:1998)<\/p>\n<p style=\"text-align: justify;\">Ammonia nitrogen (N-NH3) \u2013 Destillation unit (UNE-EN 77028:2002)<\/p>\n<p style=\"text-align: justify;\">pH, conductivity and turbidity analyzers<\/p>\n<p style=\"text-align: justify;\">Ion chromatographs with chemical suppression (IC) for the simultaneously determination of anions and cations.<\/p>\n<p style=\"text-align: justify;\">Induced coupled plasma with spectroscopy mass detector (ICP-MS) \u2013 7500ce (Agilent Technologies)<\/p>\n<p style=\"text-align: justify;\">FT-IR spectrometer<\/p>\n<p style=\"text-align: justify;\">Biological safety cabinet (Nuaire), \u00a0Sterilization autoclaves, Incubator ovens, Petri dishes rotator \/ Incubing shaker, \u00a0Quanti-Tray\u00ae sealer and Fluorescence analysis cabinet (IDEXX) for the quantification of total coliform and E. coli.<\/p>\n<p>&nbsp;<\/td>\n<\/tr>\n<tr>\n<td style=\"background-color: #a8a49d; text-align: center;\" colspan=\"2\">\n<h3><span style=\"color: #ffffff;\"><strong>CHROMATOGRAPHY TECHNIQUES<\/strong><\/span><\/h3>\n<\/td>\n<\/tr>\n<tr>\n<td><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-159\" src=\"https:\/\/grupos.unican.es\/pasep\/wp-content\/uploads\/2018\/06\/Preparacion-Muestras.jpg\" alt=\"\" width=\"296\" height=\"222\" \/><\/td>\n<td><strong>Sample Preparation<\/strong><\/p>\n<p style=\"padding-left: 30px; text-align: justify;\">Digestion\/Extraction techniques: advanced microwave digestion system, automated Soxhlet extraction unit, solid phase extraction, \u2026<\/p>\n<p style=\"padding-left: 30px; text-align: justify;\">Clean-Up techniques: Power Prep system<\/p>\n<p style=\"padding-left: 30px; text-align: justify;\">Concentration techniques: TurboVap concentration workstation, rotary evaporator<\/p>\n<p style=\"padding-left: 30px; text-align: justify;\">Liofilizator<\/p>\n<p style=\"padding-left: 30px; text-align: justify;\">Filtration systems<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-155\" src=\"https:\/\/grupos.unican.es\/pasep\/wp-content\/uploads\/2018\/06\/Ionico.jpg\" alt=\"\" width=\"296\" height=\"187\" \/><\/td>\n<td><strong>Liquid Chromatography<\/strong><\/p>\n<p style=\"padding-left: 30px; text-align: justify;\">HPLC\/MS\/MS \u2013 High performance liquid chromatograph equipped with triple quadrupole mass detector<\/p>\n<p style=\"padding-left: 30px; text-align: justify;\">IC \u2013 Ion Chromatographs with chemical supression<\/p>\n<p style=\"padding-left: 30px; text-align: justify;\">HPLC\/PDA \u2013 High performance liquid chromatograph with photodiode array detector<\/p>\n<p style=\"text-align: justify;\">For the determination of polycyclic aromatic hydrocarbons (PAHs) (UNE-ISO 16362:2006); inorganic ions (Cl-, SO42-, NO2-, NO3-, PO43-, Na+, K+, Mg2+, &#8230;) (UNE-EN 10304:2009); carboxylic organic acids (acetic, formic, oxalic); emerging micropollutants (antibiotics, pharmaceuticals, pesticides); proteins separation (casein, bovine serum albumin, ovalbumin)<\/p>\n<p>&nbsp;<\/td>\n<\/tr>\n<tr>\n<td><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-153\" src=\"https:\/\/grupos.unican.es\/pasep\/wp-content\/uploads\/2018\/06\/GCMS.jpg\" alt=\"\" width=\"296\" height=\"164\" \/><\/td>\n<td><strong>Gas Chromatography<\/strong><\/p>\n<p style=\"padding-left: 30px; text-align: justify;\">High resolution gas chromatograph HRGC-HRMS<\/p>\n<p style=\"padding-left: 30px; text-align: justify;\">GC\/MS &#8211; Gas chromatograph with spectroscopy mass detector<\/p>\n<p style=\"padding-left: 30px; text-align: justify;\">GC\/FID &#8211; Gas chromatograph equipped with flame ionization detector<\/p>\n<p style=\"text-align: justify;\">\u00a0\u00a0For the determination of volatile organic compounds (VOCs)(UNE-ISO 15009:2008); volatile halogenated hydrocarbons, included trihalomethanes (THMs) (UNE-EN 10301:1998); volatile aromatic hydrocarbons (BTEX)(UNE-ISO 15009:2008); total petrol hydrocarbons (TPHs) (ISO 16703:2004)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td style=\"background-color: #a8a49d; text-align: center;\" colspan=\"2\">\n<h3><span style=\"color: #ffffff;\"><strong>SPECTROSCOPY TECHNIQUES<\/strong><\/span><\/h3>\n<\/td>\n<\/tr>\n<tr>\n<td><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-154\" src=\"https:\/\/grupos.unican.es\/pasep\/wp-content\/uploads\/2018\/06\/Imagen2.png\" alt=\"\" width=\"296\" height=\"166\" \/><\/td>\n<td>\n<p style=\"text-align: justify;\">Spectrophotometer UV\/vis<\/p>\n<p style=\"text-align: justify;\">FT-IR spectrometer<\/p>\n<p style=\"text-align: justify;\">(ICP\/MS) Induced coupled plasma with spectroscopy mass detector, located in clean room, for the determination of elements (ppb)<\/p>\n<p style=\"text-align: justify;\">Microwave Digestion System<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td style=\"background-color: #a8a49d; text-align: center;\" colspan=\"2\">\n<h3><span style=\"color: #ffffff;\"><strong>SPECTROMETRY PLASMA MICROWAVE<\/strong><\/span><\/h3>\n<\/td>\n<\/tr>\n<tr>\n<td><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-157\" src=\"https:\/\/grupos.unican.es\/pasep\/wp-content\/uploads\/2018\/06\/Plasma-Microondas.jpg\" alt=\"\" width=\"296\" height=\"164\" \/><\/td>\n<td>\n<p style=\"text-align: justify;\">Plasma Microwave Spectrophotometer for the determination of elements in organic and aquous solutions (ppm).<\/p>\n<p>&nbsp;<\/td>\n<\/tr>\n<tr>\n<td style=\"background-color: #a8a49d; text-align: center;\" colspan=\"2\">\n<h3><span style=\"color: #ffffff;\"><strong>SOLID CHARACTERIZATION<\/strong><\/span><\/h3>\n<\/td>\n<\/tr>\n<tr>\n<td><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-156\" src=\"https:\/\/grupos.unican.es\/pasep\/wp-content\/uploads\/2018\/06\/Microscopio.jpg\" alt=\"\" width=\"296\" height=\"221\" \/><\/td>\n<td>\n<p style=\"text-align: justify;\">Thermobalance DTG-60H (<em>Shimadzu<\/em>) simultaneous DTA \u2013 TG apparatus<\/p>\n<p style=\"text-align: justify;\">BET Surface Area Measurement Analyzer<\/p>\n<p style=\"text-align: justify;\">Optical stereo-microscope 130x coupled to photo and video camera with fluorescence detector\u200b<\/p>\n<p style=\"text-align: justify;\">Zeta-sizer Nano ZS<\/p>\n<p style=\"text-align: justify;\">Osmometer<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h4><a href=\"http:\/\/web.unican.es\/departamentos\/ingquimica\/servicios\" target=\"_blank\" rel=\"noopener\">More information about Analytical Services<\/a><\/h4>\n<h2><strong>CONTACT<\/strong><\/h2>\n<h3 style=\"text-align: center;\"><strong>SERVICIOS ANAL\u00cdTICOS &#8211; Unidad SOSPROCAN<\/strong><\/h3>\n<p style=\"text-align: center;\">Departamento de Ingenier\u00edas Qu\u00edmica y Biomolecular<\/p>\n<p style=\"text-align: center;\">ETSIIyT Universidad de Cantabria<\/p>\n<p style=\"text-align: center;\">Avenida de los Castros s\/n, 39005 Santander (Espa\u00f1a)<\/p>\n<p style=\"text-align: center;\">e-mail: <a href=\"mailto:sersosprocan@unican.es\" target=\"_blank\" rel=\"noopener\">sersosprocan@unican.es<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>ENVIRONMENTAL PARAMETERS Total Organic Carbon (TOC) (UNE-EN 1484:1997) Chemical Oxygen Demand (COD) \u2013 Closed reflux and colorimetric analysis method (UNE-EN &hellip; <\/p>\n<p><a href=\"https:\/\/grupos.unican.es\/pasep\/analytical-facilites\/\" class=\"more-link\">Leer m\u00e1s<\/a><\/p>\n","protected":false},"author":2,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-150","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/grupos.unican.es\/pasep\/wp-json\/wp\/v2\/pages\/150","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/grupos.unican.es\/pasep\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/grupos.unican.es\/pasep\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/grupos.unican.es\/pasep\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/grupos.unican.es\/pasep\/wp-json\/wp\/v2\/comments?post=150"}],"version-history":[{"count":13,"href":"https:\/\/grupos.unican.es\/pasep\/wp-json\/wp\/v2\/pages\/150\/revisions"}],"predecessor-version":[{"id":519,"href":"https:\/\/grupos.unican.es\/pasep\/wp-json\/wp\/v2\/pages\/150\/revisions\/519"}],"wp:attachment":[{"href":"https:\/\/grupos.unican.es\/pasep\/wp-json\/wp\/v2\/media?parent=150"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}